Paper title: OPEN SWITCH FAULTS DETECTION AND LOCALIZATION IN THREE PHASES SHUNT ACTIVE POWER FILTER

Author(s): TARAK BENSLIMANE,

Abstract:

This paper proposes an open switch faults detection and localization algorithm for shunt three phase active filter topology. It mainly details converter configuration and examines a simple and reliable optimised fault diagnosis method. The converter topology is based on classical three-leg active power filter topology. A new fault diagnosis method is proposed, based on classical currents measurements. It includes combinatory logic to analyse and validate error signals. A Hysteresis Control is applied before and after fault detection, which avoids any controller reconfiguration. Simulation results obtained with Matlab/Simulink/Plecs tools prove the effectiveness of this method.

Keywords: Shunt active power filter, Fault detection, Two level voltage source inverter, Current mean value, Zero harmonic component, Combinatory logic.

Year: 2007 | Tome: 52 | Issue: 3 | Pp.: 359-370